Wolf Gas Burner Code Ignition Lockout: Slow-Blinking Call-for-Heat Light
On Wolf gas burners with a DSI board, including the GR304, GR484CG and SRT304, the control tries a 7-second ignition, waits a 40-second purge, tries again, then purges again before locking out. After two tries, the…
- Code
- Ignition Lockout
- Appliance
- Range
- Brand
- Wolf
- Warranty
- 30-day workmanship
What Ignition Lockout means
On Wolf gas burners with a DSI board, including the GR304, GR484CG and SRT304, the control tries a 7-second ignition, waits a 40-second purge, tries again, then purges again before locking out. After two tries, the call-for-heat light blinks slowly: that is Ignition Lockout. A fast flash is a different Safety Lockout. Turning the thermostat to OFF lets it retry.
Common causes of Ignition Lockout
- Burner failing to ignite in two 7-second trials
- Burner cap not seated or igniter wet or dirty
- Igniter, gas supply or board not completing ignition
1. If you smell gas, leave the house and call the gas utility from outside. 2. Turn the burner knob or thermostat to OFF to reset the lockout. 3. Lift the burner cap, dry it, and set it back flat and centered. 4. Wait a minute and try again once. 5. If the light blinks slowly again, call us.
- Ignition parts and the gas valve must be tested by a trained technician.
- Repeated tries can build up gas at a burner that cannot light.
Technical reference
- Code
- Ignition Lockout
- Appliance
- Wolf range
- Maker documentation
- Wolf owner manuals and support
- Checked
- October 2026
We read the code from the maker’s documentation and our own service work, and we do not reproduce the maker’s document. Always confirm the full model number before acting on a code. We are an independent repair company, not affiliated with Wolf.
Other Range codes
How many tries before the lockout?
Two ignition trials, each followed by a 40-second purge, then the control locks out. Some older guides mention three attempts, but this board uses two.
How do I tell Ignition Lockout from Safety Lockout?
Slow blink of the call-for-heat light is Ignition Lockout. A fast flash is Safety Lockout, which means flame, valve, or sensing trouble and needs service.
Can I reset it myself?
Yes, turn the thermostat to OFF to retry. If it locks out again, stop and call us, and if you smell gas, leave the area and call your gas utility from outside.
Still seeing Ignition Lockout?
A technician diagnoses it on site and gives you the price in writing before any work starts.