Wolf CI Touchscreen and Integrated Module Cooktops Code E00: Overvoltage or No Error

E00 means different things on two Wolf platforms. On CI induction touchscreen cooktops from 2023, such as the CI30460T/S and CI36560C/B, E00 is overvoltage: L1 or L2 to ground at 132 volts AC or less, and…

High · stop use, call now
Code
E00
Appliance
Cooktop
Brand
Wolf
Warranty
30-day workmanship

What E00 means

E00 means different things on two Wolf platforms. On CI induction touchscreen cooktops from 2023, such as the CI30460T/S and CI36560C/B, E00 is overvoltage: L1 or L2 to ground at 132 volts AC or less, and L1 to L2 at 265 volts AC or less, single phase. On integrated module cooktops like the CI152TF/S, E00 means no error and nothing needs repair.

Common causes of E00

  • Supply voltage outside the allowed range on a CI touchscreen model
  • Wrong supply connection at the cooktop
  • E00 shown on an integrated module as a no-error status
✓ One safe check you can try

1. Turn all zones off. 2. On a touchscreen CI model, reset the breaker after a one-minute pause. 3. Check whether E00 clears. 4. Do not retry repeatedly if it returns, and keep pans off the glass in the meantime. 5. Call us and name your cooktop model.

! Why to stop there
  • Checking supply voltage means live measurements that owners must not take.
  • Overvoltage can damage induction electronics.
Opening a panel yourself does not automatically cancel a manufacturer warranty, but it can cause accidental damage, and some manufacturers set their own service conditions. Check your warranty terms, or ask us, before deciding.
→Same appliance

Other Cooktop codes

E00E00 questions
Does E00 always mean a problem?

No. On integrated module cooktops it means no error. On CI touchscreen models from 2023 it signals an overvoltage condition. Check which platform you have first, because the very same code carries opposite meanings on the two models.

What voltage is the limit?

For single phase, L1 or L2 to ground should stay within 132 volts AC, and L1 to L2 within 265 volts AC. Those limits apply to single phase supply, and a reading outside them stops the cooktop to protect it.

Should I reset the breaker?

Once is fine. If E00 returns on a CI touchscreen cooktop, call us so we can check the supply safely. A supply check involves live measurements, so we do it safely and give you the price in writing first.