Wolf CT induction cooktops of the earlier CTI generation, like the CT30 and CT36 sizes, use E5 for an open ambient thermistor, meaning the temperature sensor circuit reads as broken. The cooktop does not record it…
Wolf CT induction cooktops of the earlier CTI generation, like the CT30 and CT36 sizes, use E5 for an open ambient thermistor, meaning the temperature sensor circuit reads as broken. The cooktop does not record it until it sees five minutes of consecutive open readings while a burner is active. After that it enters lock mode and shows E5 in the timer display. The communication board is involved in this reading.
1. Turn off all burners. 2. Wait a few minutes, then switch the cooktop breaker off for one minute and back on. 3. Try a burner again and see whether E5 and the lock return. 4. Do not remove the glass or any panels. 5. If the lock and E5 come back, book a visit so we can test the sensor circuit.
The cooktop waits for five minutes of consecutive open readings during burner activation before it records the condition. That avoids false alarms from a brief glitch.
The cooktop locks out heating and shows E5 in the timer display. A breaker reset sometimes clears the lock, but it returns if the sensor circuit is still open.
No. E4 is generator 3 heat sink too hot. E5 is about the ambient thermistor reading open, so the checks are different. It helps to note how long the code stays and whether it comes back at the same point.
A technician diagnoses it on site and gives you the price in writing before any work starts.