On Wolf's 2015 integrated module series, which includes the CE152TF/S and CI152TF/S, E5 stands for a relay error. The module's control found that its internal relay is not switching as commanded. The display flashes E5, and…
On Wolf's 2015 integrated module series, which includes the CE152TF/S and CI152TF/S, E5 stands for a relay error. The module's control found that its internal relay is not switching as commanded. The display flashes E5, and the module may fail to warm up or fail to switch off cleanly. The other modules beside it have their own controls and are not involved.
1. Turn the module off and let the surface cool. 2. If the element stays hot with controls off, switch off the breaker and call us. 3. Turn the wall circuit breaker off for one minute, then turn it on again. 4. If E5 returns, leave it off and schedule service. Do not pull it out of the counter.
That is the module model the code was listed for. The CE152TF/S is an electric module, and the same code is shown on other integrated modules in that series.
Each module has its own control, so a neighboring module can often keep working, though we suggest leaving the affected one off until we inspect it.
When the control is the cause, we can replace just that part rather than the whole module, and we confirm which part before quoting it in writing.
A technician diagnoses it on site and gives you the price in writing before any work starts.