On Wolf L Series legacy wall ovens with the Invensys control, such as the SO30F/S and SO36U/S, RELAY STUCK means a power relay is shorted. The current sensor on the oven controller sees it as closed…
On Wolf L Series legacy wall ovens with the Invensys control, such as the SO30F/S and SO36U/S, RELAY STUCK means a power relay is shorted. The current sensor on the oven controller sees it as closed when it should be open, so a heating circuit may stay energized when it should be off. The oven shows the message and may stop working or heat when it should not.
1. Switch the oven off at the breaker and leave it off. 2. Do not reach into the oven or remove panels. 3. Check that the display stays dark and the cavity is not still heating. 4. Call us for service; do not restore power until a technician checks it.
The oven's current sensor detects power flowing through a relay that should be open. That points to shorted relay contacts. The oven reports RELAY STUCK and should not be used.
If a relay is truly stuck closed, an element can stay powered. Switch the breaker off and keep it off until we inspect the oven.
No. RELAY CAL is a timing calibration problem, while RELAY STUCK is a relay sensed closed when it should be open. We tell them apart in diagnostic mode.
A technician diagnoses it on site and gives you the price in writing before any work starts.