Error code · Wall Oven

Wolf Legacy E Series Code Error 07 0 31: Relay module low-voltage fuse error

Error 07 0 31 on Wolf Legacy E Series wall ovens such as the SO30CE/B/TH reads RM LOV Fuse Error. The control reports a problem with the low-voltage fuse on the relay module. With that fuse…

High · stop use, call now
Code
Error 07 0 31
Appliance
Wall Oven
Brand
Wolf
Warranty
30-day workmanship

What Error 07 0 31 means

Error 07 0 31 on Wolf Legacy E Series wall ovens such as the SO30CE/B/TH reads RM LOV Fuse Error. The control reports a problem with the low-voltage fuse on the relay module. With that fuse not reading correctly, parts of the oven may lose power, and the code stays on the display. The 0 in this code is part of the number, so it applies to the oven control rather than to one cavity.

Common causes of Error 07 0 31

  • Low-voltage fuse on the relay module open
  • Short on the low-voltage side blowing the fuse
  • Relay module failing
✓ One safe check you can try

1. Turn the oven off and give it 30 minutes. 2. Flip the circuit breaker off, count to sixty, and switch it on. 3. Check whether the display and lights come on normally. 4. If the oven throws Error 07 0 31 again, call us and keep it off.

! Why to stop there
  • A fuse that opens usually means something drew too much current, so just replacing it can repeat the problem.
  • The relay module is inside the control area and is not an owner repair.
  • We find why the fuse opened and quote in writing first.
  • The 30-day workmanship warranty is included in the quote.
Opening a panel yourself does not automatically cancel a manufacturer warranty, but it can cause accidental damage, and some manufacturers set their own service conditions. Check your warranty terms, or ask us, before deciding.
→Same appliance

Other Wall Oven codes

Error 07 0 31Error 07 0 31 questions
What do RM and LOV stand for?

The display prints them as RM LOV, and we keep the labels. They name the relay module and its low-voltage fuse, which the control reports as not right.

Is it the same as Error 07 0 32?

It is the sister code. Error 07 0 31 is the low-voltage fuse, and Error 07 0 32 is the HIV fuse on the same relay module, so we check both.

Why not just fit a new fuse?

If a short blew it, a new fuse can open again or hide damage. We test the circuit first so the repair holds. Nothing is replaced on a guess.

Book a visit

Still seeing Error 07 0 31?

A technician diagnoses it on site and gives you the price in writing before any work starts.