What CFH light slow blink / fast flash means
On Wolf SRT rangetop griddles, charbroilers, and French tops with a DSI board, the CFH light blinking slowly signals an ignition lockout, and flashing fast signals a safety lockout. The same board family appears on GR ranges such as the GR304 and GR484CG. The burner tried to light, failed, and the board stopped sending gas. Owners see the light blinking and the burner will not light.
Common causes of CFH light slow blink / fast flash
- Ignition lockout after failed lighting attempts (slow blink)
- Safety lockout from the board (fast flash)
- Ignitor or flame sensing that is dirty or failing
- Gas supply interruption or air in the line
1. If you smell gas, leave the house and call the gas utility from outside. 2. Turn the knob off and wait several minutes. 3. Make sure the burner is dry and clean. 4. Try lighting again once. If the CFH light blinks again, stop and call us. Do not keep retrying.
- Repeated lockouts point to a part that is failing
- Gas safety lockouts should not be bypassed
- We test ignitor, flame sensing, and board together
- You approve a written price first, and the work is warranted for 30 days
Technical reference
- Code
- CFH light slow blink / fast flash
- Appliance
- Wolf rangetop
- Maker documentation
- Wolf owner manuals and support
- Checked
- October 2026
We read the code from the maker’s documentation and our own service work, and we do not reproduce the maker’s document. Always confirm the full model number before acting on a code. We are an independent repair company, not affiliated with Wolf.
Other Rangetop codes
What is the difference between slow and fast CFH blinking?
Slow means ignition lockout, after the burner failed to light. Fast means safety lockout. Both mean the board has stopped the gas, and both need the cause found.
How do I reset the lockout?
Turn the knob off and wait a few minutes, then try once. If the light blinks again, resetting will not help and a visit is needed.
Is this dangerous?
The lockout is a safety feature. If you smell gas, leave and call the gas utility from outside. Otherwise leave the burner off until we check it.
Still seeing CFH light slow blink / fast flash?
A technician diagnoses it on site and gives you the price in writing before any work starts.